Page 2 - F12-BPS-YZ102-Installation-Manual
P. 2

Introduction



                                                Table of Contents

     Page 2  Introduction                                   Page 6  Mounting & Installation
              Technical Description                                  Universal, Vertical & Horizontal Mount Purge
              Important Notes                                         Unit & Purge Vent Dimensions
              Important Manual Information Designators      Page 7  Mounting Set Up
     Page 3  Identifying Your Unit                                   Unit Mounting Instructions
              Model Number Designations                              Unit Tubing Instructions
              General Information                                    Enclosure Warning Label(s)
              Unit Specifications                           Page 8  Pressurization Unit & Switch Set Up
              Material Specifications                                Pressurization Unit Set Up
              Protected Enclosure Criteria                           Pressure Switch Set Up
              Major Components List                                  Typical Pressure Switch Wiring Diagram
     Page 4  Getting Starting                               Page 9  Pressurization Unit Operation
              Pressurization Unit & Enclosure Connection             Cross Ventilation Diagram
               Requirements                                 Page 10  Warranty & Liability Statements
              Single Enclosure Connections
              Multiple Enclosure Connections                Page 11  Factory Repair & Service Guide
     Page 5  Unit Layout                                    Page 12  Reference Information
              Unit Layout & Component Description           Page 13  Maintenance & Service Notes
              Typical Pneumatic Flow Diagram
                                                            Page 14  Unit Identification Information








                  Technical Description                                    IMPORTANT NOTE

     Model YZ102 is a Type Y or Z purge unit designed to protect   Operating  this unit  without  a Model  PV-2 Purge
     electrical equipment in Class I hazardous locations. Type Z   Vent  may cause harm, death or dismemberment to
     applications reduce the hazardous location rating inside the   personnel and can cause damage to instrumentation.
     enclosure from Division 2/ Zone 2 to non hazardous. This   This unit is NOT intended  for dilution  applications.
     allows general purpose equipment to operate in Division 2/   Please consult factory for more information.
     Zone 2 areas. Type Y applications reduce the hazardous
     location rating inside the enclosure from Division 1/ Zone 1 to   A copy of this manual must be read and retained by the
     Division 2/ Zone 2. This allows Division 2/ Zone 2 equipment   operator of this unit. User’s agent’s are responsible for
     to operate in Division 1/ Zone 1 areas.                 transferring this manual to the user prior to installation and
                                                             start up.
     Model PV-2 spark arresting Purge Vent MUST be installed
     on the protected enclosure.                             This unit must be installed and operated per this manual.
     This unit is designed to meet or exceed NEC - NFPA 70, NFPA   The  Authority Having  Jurisdiction  should  be advised
                                                             before installation of this unit. This manual DOES NOT
     496, EN 50016 and IEC 60079-02 requirements.
                                                             supersede any national, local or plant codes.
                                                               All specifications are subject to change without notice.



                                  Important Manual Information Designators

     To assist you through the installation  and operation  of your enclosure  pressurization  unit, Best Purging  Systems has provided  the
     following information boxes throughout this manual. This information is intended to clarify certain differences between the model styles
     and configurations of this unit and to warn the user and installer of potential dangers due to improper installation or operation.

           HELPFUL HINT                        IMPORTANT NOTE                             WARNING




     Page 2 of 14 BPS YZ102 IOM-R1.0                                             © 2018 - Best Purging Systems Corporation