Page 7 - F10-BPS-YZ101B-Installation-Manual
P. 7

Mounting Set Up



                       Unit Mounting Instructions                               Unit Tubing Instructions

            1.  Carefully read “Protected Enclosure Criteria” and   1.  Carefully read “Protected Enclosure Criteria” and
               “Enclosure Connection Requirements” before proceeding.  “Enclosure Connection Requirements” before proceeding.
            2.  Determine the Mounting configuration for the purge unit.   2.  The following instructions are for Units mounted external
            3.  Firmly secure the unit mounting flange, if utilized, to the   to the Protected Enclosure. Consult factory for units
               unit face plate using the hardware provided.            which are mounted inside or through the face of the
                                                                       Protected Enclosure.
            4.  Drill  and  ream  four  mounting  holes  in  the  protected
               enclosure.                                           3.  Connect 1” Protective Gas Supply Header to Unit Supply
                                                                       Connection using 3/8” .035 welded or seamless wall
            5.  Based on “Enclosure Connection Requirements,” drill    stainless steel, fully reamed tubing. Protective Gas
               and ream a 37/64” hole in protected enclosure, install   Supply tubing should not exceed 15 feet length and 5
               3/8” Enclosure Supply Bulkhead fitting. NOTE: Protected   bends.
               Enclosure Supply should be installed at extreme opposite
               corner from part # PV-3 Purge Vent (if utilized) and 8”   4.  Connect  Unit  Enclosure  Supply Connection to  the
               from the Enclosure Reference Connection.                Enclosure Supply bulkhead fitting using 3/8” .035 welded
                                                                       or seamless wall stainless steel, fully reamed tubing.
            6.  Next, drill and ream a 29/64” hole in protected enclosure,   Enclosure Supply tubing should not exceed 5 feet in
               install 1/4” Enclosure Reference Bulkhead fitting.      length and 5 bends.
            7.  If utilized, install PV-3 Purge Vent at extreme opposite   5.  MULTIPLE  ENCLOSURE  CONNECTIONS  ONLY.
               corner  from  the  Enclosure  Supply  Connection.       Connect Multiple Enclosure Protective Gas Supply Piping
               (WARNING: The PV-3 Purge Vent is gravity operated       (1 1/4” rigid pipe, fully reamed) from Protected Enclosure
               and MUST be mounted in a true vertical position.)       #1 to Protected Enclosure #2. Repeat procedure for
            8.  Install the PV-3 Purge Vent Mounting Hub through a     connection between Protected Enclosure #2 and #3.
               1-1/4” hole on the Protected Enclosure.                 Protective Gas Supply piping should not exceed 10 feet
                                                                       length and 5 bends.
            9.  Secure  the  Purge  Vent  from  inside  the  Protected
               Enclosure using the Purge Vent Mounting Nut.         6.  Connect Unit Enclosure Reference Connection to the
            10. Secure  Purge  Unit  Mounting  Flange  to  protected   Enclosure Reference bulkhead fitting using 1/4” .035
                                                                       welded or seamless wall stainless steel, fully reamed
               enclosure using hardware provided.
                                                                       tubing. Enclosure Reference tubing should not exceed
                                                                       20 feet length and 5 bends.



                                               Typical Mounting Configurations











                   Left Mount            Top Mount          Bottom Mount           Frame Mount          Right Mount


                                                 Enclosure Warning Label(s)

             Enclosure Warning Label (EWL) MUST be permanently affixed on or near all protected enclosure doors, entries and openings.
                 WARNING - PRESSURIZED ENCLOSURE                                  WARNING NOTICE
                 ENCLOSURE SHALL NOT BE OPENED UNLESS AREA IS KNOWN TO BE FREE   THIS ENCLOSURE CONTAINS HOT COMPONENTS
                 OF  FLAMMABLE  MATERIALS  OR  UNLESS A LL  DEVICES  HAVE  BEEN
                 DE-ENERGIZED. P OWER  SHALL  NOT  BE  RESTORED A FTER  ENCLOSURE   ENCLOSURE SHALL NOT BE OPENED UNLESS AREA IS KNOWN TO BE FREE
                 HAS  BEEN O PENED  UNTIL C OMBUSTIBLE  DUSTS  HAVE  BEEN  REMOVED   OF  FLAMMABLE  MATERIALS  OR  UNLESS A LL  DEVICES  HAVE  BEEN
                 AND ENCLOSURE HAS BEEN PURGED AND PRESSURIZED IN ACCORDANCE   DE-ENERGIZED FOR THE TIME SPECIFIED BELOW.
                 WITH THE UNIT START UP INSTRUCTIONS.                MINIMUM COOLONG TIME:
                                                                    BEST PURGING SYSTEMS CORPORATION     WWW.PURGEIT.COM   LA MARQUE, TEXAS USA
                    AREA CLASSIFICATION  PRESSURIZATION TYPE  TEMPERATURE CODE
               BEST PURGING SYSTEMS CORPORATION     WWW.PURGEIT.COM   LA MARQUE, TEXAS USA

            © 2018 - Best Purging Systems Corporation                                     BPS YZ101B IOM-R1.0 Page 7 of 14
   2   3   4   5   6   7   8   9   10   11   12