Page 4 - F14-BPS-YZ104-Installation-Manual
P. 4
Getting Started
Purge Unit & Enclosure Connection Requirements
1. No valves shall be installed between the Pressurization/ 5. Multiple Protected Enclosures must be purged in series
Purge Unit and the Protected Enclosure. and should be connected from the smallest to the largest
2. The Pressurization/Purge Unit should be located at eye enclosure.
level. 6. Enclosure Supply connections between multiple
3. The Pressurization/Purge Unit should be installed enclosures must be at least the diameter of the Purge
adjacent to the protected enclosure. vent exhaust (1 1/2”).
4. Enclosure Supply and Purge Vent should be installed
at extreme opposite corners, to ensure adequate purge
flow through the Protected Enclosure.
Single Enclosure Connections
Purge Vent
1” Protective Gas Model # PV-4
Supply Header
Enclosure Reference
1/4” Tubing
Protected
Unit Supply Enclosure
1/2” Tubing
Purge
Unit
Enclosure Supply
1/2” Tubing
Multiple Enclosure Connections
1” Protective Purge Vent
Gas Supply Model # PV-4
Header Enclosure Reference
1/4” Tubing
Protected
Unit Supply Protected Protected Enclosure
1/2” Tubing Purge Enclosure Enclosure #3
Unit #1 #2
Enclosure Supply Multiple Enclosure Supply
1/2” Tubing 1 1/2” Rigid Pipe
Page 4 of 14 BPS YZ104 IOM-R1.0 © 2018 - Best Purging Systems Corporation