            Tubing & Pipe  Model BBCF, BFCF,   Pressure Loss Alarm Switch   Model EPSK  Required Accessories for ALL  Model EPWN &
          Bulkhead Connections for ALL        Accessory for ALL Universal Mount      Protected Enclosures
          Purging & Pressurization Systems  BFFK & EPC  Purging & Pressurization Systems  Configurations CD,   ETWN
                                                                 B24, B120 & B240
              BBCF                                Description                         EPWN Nameplate  Enclosure Pressure & Enclosure Temperature
                                                               Explosion Proof
         The Model BBCF Bulkhead Connection Kit provides     Tubing & Pipe Bulkhead Connection Kits  Model EPSK Explosion Proof Enclosure Pressure   Enclosure Pressure Switch Kits  Model EPWN Enclosure Pressurization Warning   Warning Nameplates
         standard nut and ferule tubing connections to a   Switch Kits are accessories that provide a pressure   Nameplates are intended for all protected
         protected enclosure for a purging or pressurization   loss alarm contact.  They are intended to mount   enclosures.  One (1) nameplate is furnished with
         system’s supply and reference tubing. The Model   Technical Bulletin BCK TB-R0   © 06.20.2018  in a vertical stand-alone position to complement   Technical Bulletin EPSK TB-R0   © 07.10.2018  all Pressurization and Purging Units, but additional   Technical Bulletin EWN TB-R0   © 07.10.2018
         BBCF consists of one 1/4” through wall stainless   all universal mount Type Y and Z purging and   nameplates must be ordered separately at time of
         steel bulkhead fitting for atmospheric reference and   pressurization systems, and are offered in a full   order to label all doors of the protected enclosure,
         one 1/4”, 3/8” or 1/2” through wall stainless steel   range of area classification ratings to satisfy any   as required by NFPA 496.
         bulkhead fitting, depending on model selected, for   Hazardous Location.
         the supply connection to the protected enclosure.                         These nameplates are an essential accessory
                                                 Applications                      and required by NFPA 496 to ensure operators
                                                                                   and maintenance personnel are advised that
              BFCF                                                                 they must not open the protected enclosure while
                                              When utilized in conjunction with one or more of our   internal devices that are not suitable for use in
         The Model BFCF Bulkhead Connection Kit provides     Model RAB Remote Alarm Beacon or Model RAH   the  Hazardous Area  are  energized.   To  meet
         standard nut and ferule tubing connections to a   Remote Alarm Horn devices, or any pre-existing or   protected enclosure labeling requirements for both
         protected enclosure for a purging or pressurization   common alarm device or system, these Enclosure   Class I and Class II, the warning also prescribes
         system’s supply and reference tubing. The Model   Pressure Switch Kits can be utilized to activate the   that all combustible dust must be removed from
         BFCF consists of one 1/4” flush mount stainless   alarm devices or system to gain the attention of   the protected enclosure and it must be properly
         steel bulkhead fitting for atmospheric reference and   Model BBCF  operators and maintenance personnel upon the   purged or pressurized after it is opened, before
         one 1/4”, 3/8” or 1/2” through wall stainless steel   Through Wall Supply & Reference  loss of safe pressure in a protected enclosure.  re-energizing  any  internal  devices  that  are  not
         bulkhead fitting, depending on model selected, for   Bulkhead Connection Kit  suitable for use in the Hazardous Area.
         the supply connection to the protected enclosure.
                                                  Provisions
              FFCF                            Model EPSK Enclosure Pressure Switch Kits   ETWN Nameplate
         The Model FFCF Bulkhead Connection Kit provides    include a rated pressure switch to meet your   Model ETWN Enclosure  Temperature Warning   Model
                                                                                                      EPWN
                                              particular area classification, and a combination
         standard nut and ferule tubing connections to a   of one or two atmospheric reference vents, a   Nameplates are intended for protected enclosures
         protected enclosure for a purging or pressurization   male 1/4” tubing connector a flush or female pipe   that feature internal devices with surface
         system’s supply and reference tubing. The Model   bulkhead connector and a set of 1/4” fasteners to   temperatures that exceed the T Code Rating of
         FFCF consists of one 1/4” flush mount stainless   attach the switch securely, whether mounted inside   the surrounding Hazardous  Area  atmosphere.
         steel bulkhead fitting for atmospheric reference and   or exterior to a protected enclosure.  These items must be ordered separately at time
         one 1/4”, 3/8” or 1/2” flush mount stainless steel          Certifications Vary   of  order  and  are required  for  all  doors  of  the
         bulkhead fitting, depending on model selected, for          please contact us for   protected enclosure.
         the supply connection to the protected enclosure.  Installation  more information  They are an essential accessory and required by
              EPC          Model BFCF         Model EPSK Enclosure Pressure Switch Kit must   NFPA 496 to ensure operators and maintenance
                                                                                   personnel are advised that they must wait for
                                              be installed in a vertical position on a secure
         The Model EPC Enclosure Pipe Connection Kit   Through Wall Supply & Flush Reference  surface.  The high port of the switch must reference   the established time period before opening the
                                                                                   protected enclosure to prevent ignition of the
                         Bulkhead Connection Kit
                                              the protected enclosure atmosphere or the last
         provides an NPT connection to a protected enclosure   enclosure of an array, while the low port must   surrounding atmosphere.   The cooling time in
         for piping between multiple purged or pressurized   reference  external  atmosphere.   All  Switches   minutes  must  be  determined  by  the  user and
         enclosures. The Model EPC consists of two 3/4”,   feature a 1/2” FPT female pipe thread port for the   inscribed on the nameplate at time of installation,
         1 1/4” or 1 1/2” flush mount zinc die cast bulkhead   connection of suitable conduit to an alarm device.  or you may request the inscription at time of order
         fittings.                                                                 if already established and known.
                                                Calibration & Operation                               Model
                                              Calibration of the .07” to .15” W.C. set point is   Specifications  ETWN
                                              accomplished by adjusting a set screw on the side
                                              of the Switches, and there is an inherent delay to   Dimensions:   5” W x 2” H
                                              switch action created by the restriction of air flow   Mounting Hole Diameter:   0.125”
                                                                    Interior Switch
                                                           Exterior Switch
                                              through the Switch’s flame arresting pressure ports.   Location Hardware  Location Hardware  Adhesive Backing:   * 3M VHB  Achieve total compliance to NFPA 496 by applying
                                                                                        0.10” Anodized Aluminum
                                              The CD Configuration Switch features a Form C   Material:   Silk-Screened Enamel Paint   these labels to all doors of your protected enclosure!
                                                                                   Legends:
                           Model FFCF         contact that is activated mechanically by the switch   Both hardware kits include all essential fittings
                         Flush Mount Supply & Reference  diaphragm.  Switch Configurations B24, B120 &   and fasteners to complete switch installation,   * Door surfaces must be cleaned for maximum adhesion.
                                                                                                   Please contact a Sales Associate
                                              B240 each require a power source to energize their
             Model EPC   Bulkhead Connection Kit  Form C contacts. - see image on Page 2  less electrical conduit fittings  All Specifications subject to change without notice.  for more information and customization options.
                                                                                   3M & VHB are trademarks of the 3M Corporation
           Enclosure Pipe Connection Kit
                       Copyright © 2018 - Best Purging Systems Corporation All Rights Reserved   Copyright © 2018 - Best Purging Systems Corporation All Rights Reserved   Copyright © 2018 - Best Purging Systems Corporation All Rights Reserved
            PIAD Description  Model PIAD       Panel Mounting Gaskets and   Model PMGK  Purging & Pressurization  Model RAB & RAH
         Model PIAD Purgeable Instrument Access Doors are custom built   Purgeable Instrument   Essential Fittings to adapt all  Unit Accessories  Remote Alarm Devices
         doors with mounting frames manufactured to meet or exceed   Universal Mount Model YZ Units
         NEMA 12 (IP 52) or NEMA 4 or 4X (IP 56) ratings.  Access Doors  Panel Mount
         They are intended for any application, and come in an array of   Gasket Kits  Typical Applications
         sizes and features, manufactured to your exact specifications.  Our   Kit Applications
         PIADs are designed to cover electrical devices which penetrate   For Panel or Surface Mounted Devices in Purged,   Model  RAH, RAB & ERAB  Alarm Beacons  and Horns   Class I, Division 1 & 2
         the surface of an enclosure and are unsuitable for exposure to   Model  PMGK  Panel Mount Gasket Kits permit   Universal Mount Model YZ Unit Conversion Kits  are intended  to provide  local alarms for unit faults, high
         the surrounding corrosive, hazardous or classified atmosphere.   Pressurized, Outdoor or Corrosive Area Enclosures  installation of Universal Mount Model YZ Units   temperatures, loss of pressurization or ventilation and other   Alarm System Beacons & Horns
         Designed for rugged duty, all Best Purging Systems PIADs feature   through a cutout in any surface or door of a   situations that require immediate attention from local operators
         14 gauge carbon steel, aluminum or stainless steel mounting   Technical Bulletin PIAD TB-R1.1   © 06.05.2020  protected enclosure.  Installed in this manner,   Technical Bulletin PMGK TB-R0   08.10.2018  and maintenance staff  members. They  work in conjunction   Technical Bulletin RAD TB-R0   © 06.08.2018
         frames and doors, removable stainless steel hinges,1/4” Laminated   the unit becomes an integral part of the protected   with any Unit featuring a pressure loss alarm switch, and may
         Safety Glass, Lexan™ Margard™  MR-10  or Wire Reinforced   enclosure, rather than being mounted externally at   also serve as common alarms for other equipment.
         Safety Glass windows with a proprietary shock-resistant mounting   a perpendicular angle.
         system, and replaceable, life-time warranty door gasket, with an
         NFPA 496 purged enclosure warning nameplate, mounting sealant   Utilize these kits to boost aesthetic and ergonomic
         and mounting hardware.               values of protected enclosures, minimize the overall     RAH-1 Horn Description
         Standard finishes include vertical or horizontal brush finishes for   foot-print of protected enclosures in confined   Model RAH-1 horns provide an electrically generated audible
         stainless steel, a black anodized finish for aluminum or an enamel   spaces and minimize exposed mechanical surface   alarm. Corrosion resistance is achieved with a copper–free
         paint finish on any material. Custom finishes are also available   areas of protected enclosures in clean rooms.  cast  aluminum housing, and this  horn features a  vibrating
         and door fastening options include hand, key or tool actuated vice        stainless steel diaphragm.  The horn is rated for Class I or II,
         action compression latches in black polyester powder coated die           Division 1 or 2 hazardous locations, can be pendant or wall
         cast zinc or electro-polished 316 grade stainless steel materials.  Kit Features  mounted and features a 3/4” female conduit port. The horn
                                NEMA 12                                            has a 100 dBa output at a distance of 10’ with a 5 minute duty
           PIAD NEMA Ratings     Rating       Model PMGK kits feature a unit mounting plate   cycle, and the 120 VAC and 240 VAC versions feature an
                                                                                   internally mounted volume control for field adjustment.
                                              gasket and an enclosure pressure gauge gasket
                                              to provide a positive seal.  They also  include
         As a critical design option, Purgeable Instrument Access Doors   two bulkhead unions, an atmospheric pressure
         from Best  Purging Systems Corporation are manufactured to   reference vent fitting and essential bulkhead labels.  Model   Model   Model   RAH-2 Horn Description  See
         meet or exceed NEMA ratings ranging from NEMA 12, 4 and 4X,                            Model RAH-1-P-C  and dome
                                                                                                             mounting
         to satisfy increasingly harsh indoor or outdoor applications and   PMGK-101A  PMGK-101B  PMGK-101C  Model RAH-2 horns produce sound by the electro–mechanical   ALARM HORN  guard options
                                                                                                             on Page 2
         exposure to rain, wash-down and corrosive chemicals.  Utilization Requirements  vibration of a stainless steel diaphragm. The housing is water
                                                                                   and dust–tight, making it suitable for indoor or outdoor use.
          NEMA   Material Options &   IP                    Each Model PMGK        The horn can be pendant or wall mounted and features a die–  Model RAB-1-C-C
          Rating   Resistance Parameters   Rating  To utilize a Model PMGK on a universal mount   Kit Includes Essential   cast zinc housing  with a corrosion–resistant  polyurethane   ALARM BEACON
           12   14 Gauge Carbon Steel or   52  pressurization or purging unit, an installer must   Bulkhead Labels!  finish. This horn is rated for Class I & II, Division 2 hazardous
                                              perform a simple modification to reverse the
             3/32” 5052 Aluminum                                                   locations, produces 100 dBa at a distance of 10’, produces
          PIAD constructed for indoor use to provide a degree of protection  locations of a tubing connector fitting and a vent   sustained or coded tones, and includes a fused terminal block
         to personnel against incidental contact with the enclosed equipment  fitting on the back of the enclosure pressure gauge.  connection.
         and to provide a degree of protection against the ingress of dust, dirt,  Furnished complete with
           and dripping non-corrosive liquids, oil and lubricants.  Installation Manual, NFPA   The sealing gaskets must then be applied to the
           12   14 Gauge 304 or 316 Grade   52  Purged Enclosure Warning   unit mounting plate and enclosure pressure gauge   RAB-1 Beacon Description
                                              to form a seal resistant to rain and light wash down.
             Stainless Steel  Nameplate, Sealant &
          PIAD constructed for indoor use to provide a degree of protection        Model  RAB-1 beacons  provide  visual  alarms at 80 high–
         to personnel against incidental contact with the enclosed equipment;  Mounting Hardware!  The protective gas  supply and  atmospheric   intensity  flashes  per  minute.  The  beacon  is  formed  from
          to provide a degree of protection against the ingress of dust, dirt,  reference bulkhead unions must then be installed   cast  aluminum  with  an  epoxy  finish,  is  corrosion  resistant
          and dripping non-corrosive liquids, oil and lubricants, and to resist  through an external surface of the protected   and features a strobe tube bulb rated for 10,000 hours.
          damage caused by exposure to atmospheres containing  enclosure, which must then be connected to the   The beacon is rated for Class I or II, Division 1 hazardous   Model RAH-2-S-C
            corrosive gases, dusts or vapors. *  unit with tubing to provide a suitable source of   locations, offered in pendant, wall or ceiling mounting styles   ALARM HORN
            4   14 Gauge Carbon Steel or   56  NEMA 4 & 4X   protective gas and a reference to atmospheric   with 3/4” female conduit ports and an optional dome guard.
                                              pressure.  As an extra benefit, labels are supplied
             3/32” 5052 Aluminum
          PIAD constructed for indoor or outdoor use to provide a degree of  Ratings  for both bulkhead unions to identify their purpose.
         protection to personnel against incidental contact with the enclosed        RAB-2 Beacon Description
          equipment; to provide a degree of protection against falling dirt,  For more information, please see complete   Model RAB-2-P-C
          rain, sleet, snow, windblown dust, splashing water, and  Conversion and Installation Details on Page 2.  Model RAB-2 has an LED lamp rated for 50,000 hours
           hose-directed water; and that will be undamaged                                              ALARM BEACON
           by the external formation of ice on the PIAD.                           with 60 high intensity flashes per minute or a steady burn.    CERTIFIED
                                                                                   This beacon is rated for Class I or II, Division 2 hazardous
                                                                      Model
                                                           Model
                                                                 Model
           4X   14 Gauge 304 or 316 Grade   56  Material Specifications  PMGK-102  PMGK-103  PMGK-104  locations,  has a 2,000,000  peak candlepower  rating.  It
             Stainless Steel
                                                                                   features a red fresnel lens and dome guard and is available in
          PIAD constructed for indoor or outdoor use to provide a degree of        pendant or ceiling mounting styles.
         protection to personnel against incidental contact with the enclosed   Unit Gasket:   1/8” Closed Cell Neoprene
          equipment; to provide a degree of protection against falling dirt,  Gauge Gasket:   Butyl Rubber  Six Unique PMGK Panel Mount
           rain, sleet, snow, windblown dust, splashing water,  Union Bodies & Ferrules:   316 Stainless Steel  ERAB-2 Beacon Description
           hose-directed water and corrosion; and that will be
          undamaged by the external formation of ice on the PIAD.  Shown with custom   Union Fitting Nuts:   Molybdenum disulfide  Gasket Kits provide a total solution!   Model ERAB-2 is an economical  alternative, has a strobe   Certifications vary
                                                                                                 Please see Page 2
             * IMPORTANT NOTE  door positioning      coated 316 Stainless Steel  Each Model PMGK kit includes all necessary components to   tube rated for 10,000 hours with 80 high intensity flashes per
         The addition of resistance to corrosive atmospheres is an enhancement by the Best   Atmospheric Vent:   316 Stainless Steel Body  easily adapt a matching universal mount unit for sealed panel   minute or a steady burn.  This beacon is rated for Class I or II,
                                                                                                Contact our factory for optional
         Purging Systems Corporation to the standard NEMA definition for a NEMA 12 rating.  hardware!     304 Stainless Steel Element   mounting through a protected enclosure surface cutout.  Division 2 hazardous locations, features a red lens and globe   Model RAB-1 & RAB-2 dome guards and   Model ERAB-2-P-C
                                                                                   guard and is available in a pendant mounting style.  alternate Model RAB and ERAB dome colors!  ECONOMY ALARM BEACON
                       Copyright © 2020 - Best Purging Systems Corporation All Rights Reserved   Copyright © 2018 - Best Purging Systems Corporation All Rights Reserved
                                                Redundant Overpressure  Model RR-4,
                                                Protection Regulators for
                                               Model 101A, 101B & 101C Units  RR-6, & RR-8
                                                  Application
                                                              Overpressure Protection
                                              Model RR Redundant Regulators are intended to   Redundant Regulators
                                              satisfy NFPA 496 requirements for preventing the
                                              possibility of enclosure over-pressurization due to
                                              excessive protective gas supply pressure.    Technical Bulletin RR TB-R0   © 07.20.2018
                                              Each regulator features a removable adjustment
                                              knob to render it tamper-proof at the user’s
                                              discretion. The regulators feature a 0-30 psi gauge,
                                              and when installed upstream of a Model 101A,
                                              101B or 101C Enclosure Pressurization Unit, and
                                              properly calibrated as recommended on page 2,
                                              will serve as an up-stream protective gas supply
                                              safety device.
                                              Model RR Redundant Regulators are identical to
                                              the Enclosure Pressure Control Regulators of the
                                              Units they protect, so the adjustment knobs of both
                                              regulators are interchangeable if needed.
                                               Optional Installation Kits
                                              Model RR Redundant Regulators are suitable for
                                              in-line mounting and may be adequately supported
                                              by threaded pipe headers.    All Models are
                                                                   offered with optional
                                              However, we offer optional  industrial grade   Mounting Hardware &
                                              mounting hardware and tube fittings to facilitate
                                              the proper installation of these regulators.  Tube Fitting Kits!
                                              The kits include a 14 gauge 316 stainless steel
                                              regulator bracket, a regulator mounting ring,
                                              neoprene o-ring sealing screws, neoprene gasket
                                              backed 18-8 stainless steel sealing washers, 316
                                              stainless steel nylon locking nuts and two 316
                                              stainless steel 90 degree elbow tube fittings.
                                                Alternative Solution
                                              In  certain  circumstances,  such  as  an  analyzer
                                              or  process  measurement  meter  application,  a
                                              protected enclosure may contain other potential
                                              sources of high pressure gases, in either
                                              combustible, flammable or inert compositions.
                                              We therefore offer Model PV Purge Vents
                                              as a viable alternative for protection against
                                              excessive protective gas supply pressure and
                                              over-pressurization  due to other  sources  of
                                              internal overpressure.  Consider this alternative if
                                              warranted by your application, and contact a Sales
                                              Associate for more information.
                                                    Model PV Vents
                                                    can act to relieve
                                                   excessive protective
                                                   gas supply AND internal
                                                   sources of overpressure!