Conversion & Installation Details                              Model Number Matrix

            Step 1:                                                Typical Model Number:                    PMGK - 101A
            Carefully remove the enclosure pressure gauge from the unit   Model Series Number
            and reverse or swap the positions of the tubing connector   Kit Size
            and vent fitting on the back of the enclosure gauge.  Place   101A  -  Compatible with Model YZ101A
            the  sealing gasket on the  enclosure pressure gauge and
            carefully reinstall it, taking care to not over-torque the screws.   101B  -   Compatible with Model YZ101B
                                                                   101C  -   Compatible with Model YZ101C
                                                                   102   -   Compatible with Model YZ102
                                                                   103   -   Compatible with Model YZ103
                                                                   104   -  Compatible with Model YZ104


                                                                     Unit, Cutout & Bolt Hole Dimensions

                                                                         Models YZ101A, YZ101B & YZ101C
                                                                                            (b)



                     BEFORE                     AFTER                                         (a)           Four (4)

                                DO NOT MOVE                                      (b)                        0.25” Ø
                                 FITTINGS ON                                                               Bolt Holes
                                   SIDE OF
                                   GAUGE

                                                                   Model    Unit Plate     Cutout (a)   Hole Centers (b)
                                                                   YZ101A     8” x 8”       6” x 6”            7”
                                                                   YZ101B     9” x 9”       7” x 7”            8”
                                                                   YZ101C     9” x 9”       7” x 7”            8”

            Step 2:                                                         Models YZ102, YZ103 & YZ104
            Apply the unit mounting plate gasket to the rear surface of                (b)       (b)
            the unit.

                                                                               (b)
                To                                                                            (a)          Eight (8)
             Suitable                                                                                       0.25” Ø
             Source of                                To Female                                            Bolt Holes
            Protective                                 Bulkhead                (b)
               Gas                                      Union
                                                        & Vent
                                                        Fitting    Model    Unit Plate     Cutout (a)   Hole Centers (b)
                                                                   YZ102     12” x 12”     10” x 10”          5.5”
                                                                   YZ103     12” x 12”     10” x 10”          5.5”
                                                                   YZ104  14.5” x 14.5”   12.5” x 12.5”      6.75”
            Step 3:                                                             IMPORTANT NOTES

            Install the unit in the protected enclosure’s cutout and install   1.  A properly sized and installed Model RR Redundant Regulator
            the bulkhead  unions  through the protected enclosure’s   or Model PV Purge Vent is strongly recommended when this kit
            external surface.  Using rigid or flexible tubing, connect the   is utilized to install Model YZ101A, YZ101B or YZ101C Units.
            unit regulator air supply fitting to a suitable protective gas   2.  Tubing from the Enclosure Supply Fitting of Model  YZ102,
            source and connect the low port of the enclosure pressure   YZ103 & YZ104 Units should be internally routed to attain the
            gauge to the atmospheric pressure reference vent. Supplied   maximum degree of cross ventilation from the Enclosure Purge
            labels may then be applied to properly identify the bulkheads.  Vent in complete accordance with NFPA 496 requirements.

                This kit may be factory installed - please contact a sales associate for more information!

                         Specifications subject to change without notice, warranty & liability statements available upon request.